WITT EscS 3 | PÜWE Potential monitoring device

WITT EscS 6 | PÜWE

Potential monitoring device infeed

SKU: 00000093 Categories: Class 4 VLD, voltage limiting device
  • Description
  • Additional information

Description

Application

The potential monitoring device WITT EscS (PÜWE) determines the potential difference between two connection points and short-circuits it for a limited time when a preset voltage level (40 to 99 volts) is exceeded.

Description

If the preset voltage level is exceeded, the WITT EscS (PÜWE) responds, i.e. anti-parallel connected thyristors are triggered and a contactor is switched at the same time. The two connections are short-circuited.
After the preset time (8 to 60 seconds) has elapsed, the connection is canceled again.
The number of switching operations is counted. If there are more than five switching operations per hour, an error message is generated, otherwise the counter is reset.
The switch-on threshold is set on the display in one-volt steps and applies to AC and DC voltages.
In the event of excess temperature (factory setting 60 ° C) or a defective contactor, the PÜWE is switched to inactive, i.e. it is not switched on.

Function

The following messages are generated by the WITT EscS (PÜWE) and are available on potential-free contacts:

  • Operation WITT EscS (PÜWE) in normal operation, open
  • Short circuit WITT EscS (PÜWE) is closed
  • Error PÜWE has carried out more than 5 switching operations per hour
  • Overtemperature WITT EscS (PÜWE) Internal temperature has reached the limit value, device is inactive

The properties described under the tab “ Technical data ” also contain possible options that we offer for the product. If you are interested, please contact us.

Additional information

Approvals

Witt

Normen

Customer requirement, DIN EN 50121-05, DIN EN 50122-02, DIN EN 50123-01, DIN EN 50163, DIN EN 50526-02

Switch-on capacity (Inss)

14 kA / 25 ms

DC System voltage (UA)

Witt

Auxiliary voltage (1)

110 V DC, 240 VAC / 50 Hz, 24VDC, 48VDC, 60VDC

Auxiliary voltage (2)

110 V AC / 60 Hz, 110 V DC, 230 V DC, 240 VAC / 50 Hz, 24VDC, 48 V DC, 60VDC, Customer request, No

SCADA wireless communication

GSM, LTE, No, W-LAN

SCADA communication protocol

No

Controls

Witt

Housing type

compact cabin GFK, Control cabinet stainless steel

Protection class according to DIN EN 60529

Witt, Witt

Exterior color

Witt

Auxiliary voltage buffered

No

Documentation type

digital, Paper

You may also like…

  • EscS P1000 mobile testing device EKS-P1000

    WITT EscS P1000 mobile testing device

    Read more
  • Placeholder

    Installation for walls for VLD Systems

    Read more
  • GFK In-ground base

    In-ground base for VLD-Systems (outdoor)

    Read more

Related products

  • Earth potential measuring device WITT EPM 3 | EPM 80

    Read more
  • transducer TD1A01 0 – 60 mV to 4 – 20 mA

    Transducer TD1A01 0 – 60 mV to 4 – 20 mA

    Read more
  • Placeholder

    Installation of combat cabine for pole

    Read more

Explore more

Get our Travel Guide Get Inspiration Get Connected

Footer

WITT Solutions GmbH

Dyrotzer Ring 3

14641 Wustermark bei Berlin
Germany

Tel. +49 33234 243 30
Fax +49 33234 243 302

 

© 2023 witt-solutions.de · WITT Solutions GmbH · Wustermark / Germany · GF Klaus Gradischek

Keep In Touch

  • Facebook
  • GitHub
  • Instagram
  • Pinterest
  • Twitter
  • YouTube
  • Contact
  • Privacy policy
  • Impressum
  • Career
  • General terms and conditions
  • Deutsch