WITT-Bridge measurement components

WITT Bridge components feature a voltage-resistant analogue measuring stage and intelligent evaluation functions. All available measurement data can be transferred within the WB measurement platform or to third-party systems for measurement data acquisition.

Measurement and evaluation are performed autonomously in the respective systems without the need for third-party systems.

Optional functions and customer-specific adaptations allow these to be tailored to your specific requirements.

Showing 1–12 of 15 results

  • WITT-Bridge Extension

    WITT-Bridge Extension (3)

  • Cable monitoring for DC cables

    Cable monitoring for DC cables

    The WITT WB-CM3 monitors the insulation between the shield or conductor and an earthing point and signals the event via potential-free signaling contacts. Measurement data can also be transferred to third-party systems.

    The WITT WB-CM3 monitors the insulation between the shield or conductor and an earthing point and signals the event via potential-free signaling contacts. Measurement data can also be transferred to third-party systems.

  • WB Data Concentrator (WB-DZ): Embedded system for the WB measurement platform

    WB Data Concentrator (WB-DZ): Embedded system for the WB measurement platform

    Powerful embedded system for the WB measurement platform – integrated via WB backplane bus, stores measurement data, provides web pages, supports IEC 61850, graphical evaluations, SD/SSD memory and central parameter management. (200 characters)

    Powerful embedded system for the WB measurement platform – integrated via WB backplane bus, stores measurement data, provides web pages, supports IEC 61850, graphical evaluations, SD/SSD memory and central parameter management. (200 characters)

  • WB-AI – analogue input card

    WB-AI – analogue input card

    Measures DC voltages and AC components
    Voltage withstand rating up to 6,000 V DC

    Measures DC voltages and AC components
    Voltage withstand rating up to 6,000 V DC

  • WB-AP battery pack for MSR components

    WB-AP battery pack for MSR components

    The WB-AP supplies WB measurement, control and regulation modules – such as the WB-VLDM – with battery power for autonomous operation, whilst monitoring the voltage and temperature of the batteries in use. There are three versions to choose from: WB-AP S (up to four batteries, each with a capacity of 3,400 mAh), WB-AP M (up to three batteries, each with a capacity of 7,000 mAh) and WB-AP XL, which can be expanded with external battery packs to provide mass storage. Optionally, the capacity can be recharged via a solar panel – ideal for locations without a fixed

    The WB-AP supplies WB measurement, control and regulation modules – such as the WB-VLDM – with battery power for autonomous operation, whilst monitoring the voltage and temperature of the batteries in use. There are three versions to choose from: WB-AP S (up to four batteries, each with a capacity of 3,400 mAh), WB-AP M (up to three batteries, each with a capacity of 7,000 mAh) and WB-AP XL, which can be expanded with external battery packs to provide mass storage. Optionally, the capacity can be recharged via a solar panel – ideal for locations without a fixed

  • WB-CAI | WB component for calculating electrical currents

    WB-CAI | WB component for calculating electrical currents

    Determines direct currents and their directions of flow.

    • Continuous voltage withstand: 3000 VDC

    • high safety standards

    Determines direct currents and their directions of flow.

    • Continuous voltage withstand: 3000 VDC

    • high safety standards

  • WB-DI 4

    WB-DI 4

    Expansion of a WB component to include up to four digital inputs

    Expansion of a WB component to include up to four digital inputs

  • WB-DO

    WB-DO

    WITT Bridge Digital Outputs

    High separation voltage of up to 2000 VDC / 20ms

    WITT Bridge Digital Outputs

    High separation voltage of up to 2000 VDC / 20ms

  • WB-MC

    WB-MC

    Communicative interlinking of WB components

    Communicative interlinking of WB components

  • WB_Service Case T2

    WB-SC Service Case T2

    Challenges of Modern Measurement, Control, and Regulation Systems
    The configuration and maintenance of modern measurement, control, and regulation systems are becoming increasingly complex.

    Challenges of Modern Measurement, Control, and Regulation Systems
    The configuration and maintenance of modern measurement, control, and regulation systems are becoming increasingly complex.

  • WB-Terminal adapter

    WB-Terminal adapter

    The WB Terminal Adapter media converter connects a standard USB port to the VLDM interface, enabling configuration and firmware updates.

    The WB Terminal Adapter media converter connects a standard USB port to the VLDM interface, enabling configuration and firmware updates.

  • WB-TVM Voltage Relays and Data Acquisition

    WB-TVM Voltage Relays and Data Acquisition

    Monitoring relay. Using robust analogue and digital measurement technology, the DC voltage is measured, analysed, signalled and transmitted to a data collector.

    Monitoring relay. Using robust analogue and digital measurement technology, the DC voltage is measured, analysed, signalled and transmitted to a data collector.

  • WB-VLDM: permanent monitoring of SDS and HVL

    WB-VLDM: permanent monitoring of SDS and HVL

    The WB-VLDM continuously monitors voltage breakdown fuses (SDS) or hybrid voltage limiters (HVL) in accordance with DIN EN 50526-2, Class 1, 2.1 or 2.2. It detects breakdowns and switching operations in real time. Detected events and regular status updates can be reported via text message or email to up to ten recipients. No cloud connection required.

    Various power sources are available for the ultra-low-power component (battery, auxiliary power supplies and traction current).

    The WB-VLDM continuously monitors voltage breakdown fuses (SDS) or hybrid voltage limiters (HVL) in accordance with DIN EN 50526-2, Class 1, 2.1 or 2.2. It detects breakdowns and switching operations in real time. Detected events and regular status updates can be reported via text message or email to up to ten recipients. No cloud connection required.

    Various power sources are available for the ultra-low-power component (battery, auxiliary power supplies and traction current).