600 VDC

Fahrspannungen bis 600VDC

Showing all 10 results

  • Cable monitoring for DC cables

    Cable monitoring for DC cables

    The WITT WB-CM3 monitors the insulation between the shield or conductor and an earthing point and signals the event via potential-free signaling contacts. Measurement data can also be transferred to third-party systems.

    The WITT WB-CM3 monitors the insulation between the shield or conductor and an earthing point and signals the event via potential-free signaling contacts. Measurement data can also be transferred to third-party systems.

  • TVM-System

    TVM system: Underground tunnel – voltage detection relay

    The WITT TVM system monitors the traction voltage in both directions of travel using a single, factory-preconfigured unit – ideal for installation in underground railway tunnels. Up to two TVM components – analogue voltage monitors or voltage signalling relays – are housed in a highly compact V2A stainless steel enclosure, which can withstand even severe external impacts such as rockfall or vandalism. Highly insulating separation zones within the enclosure prevent voltage cross-contamination between the different voltage ranges, as well as between the operating and signalling voltages. The system is supplied ready for operation and fully configured – there is no need for on-site commissioning or parameterisation.

    The WITT TVM system monitors the traction voltage in both directions of travel using a single, factory-preconfigured unit – ideal for installation in underground railway tunnels. Up to two TVM components – analogue voltage monitors or voltage signalling relays – are housed in a highly compact V2A stainless steel enclosure, which can withstand even severe external impacts such as rockfall or vandalism. Highly insulating separation zones within the enclosure prevent voltage cross-contamination between the different voltage ranges, as well as between the operating and signalling voltages. The system is supplied ready for operation and fully configured – there is no need for on-site commissioning or parameterisation.

  • WITT CM 200 cable monitoring

    WITT CM 200 cable monitoring

    The fully analog CM200 is used to detect changes between two potentials. A typical application is monitoring shields for insulation faults or interruptions.
    The operating status is indicated by LEDs or potential-free signal contacts. The CM 200 operates without auxiliary power.

    The fully analog CM200 is used to detect changes between two potentials. A typical application is monitoring shields for insulation faults or interruptions.
    The operating status is indicated by LEDs or potential-free signal contacts. The CM 200 operates without auxiliary power.

  • WITT EPM 100 | Earth potential tester

    WITT EPM 100 | Earth potential tester

    Voltage monitoring between the track earth and the water earth serves to prevent corrosion, ensure safety, detect faults and comply with regulations.

    Voltage monitoring between the track earth and the water earth serves to prevent corrosion, ensure safety, detect faults and comply with regulations.

  • EscS Schema

    WITT EscS Produktlinie: Erdungskurzschließer/VLD konfigurieren

    Die WITT EscS (Earth short-circuiter) Produktlinie ist unser konfigurierbarer Baukasten für Erdungskurzschließer bzw. Spannungsbegrenzungseinrichtungen (VLD) der Klasse 3 und 4 in Gleichstrombahnen. Sie baut auf den WB-Komponenten auf, ist technisch auf dem neuesten Stand und besteht nicht aus einem fertigen Gerät, sondern aus Bausteinen: Im Reiter „Konfiguration“ stellen Sie Ihren EscS selbst zusammen – bis zu 5.000 Varianten sind möglich. Wir prüfen Ihre Konfiguration, klären bei Bedarf offene Punkte mit Ihnen und erstellen Ihr Angebot.

    Die WITT EscS (Earth short-circuiter) Produktlinie ist unser konfigurierbarer Baukasten für Erdungskurzschließer bzw. Spannungsbegrenzungseinrichtungen (VLD) der Klasse 3 und 4 in Gleichstrombahnen. Sie baut auf den WB-Komponenten auf, ist technisch auf dem neuesten Stand und besteht nicht aus einem fertigen Gerät, sondern aus Bausteinen: Im Reiter „Konfiguration“ stellen Sie Ihren EscS selbst zusammen – bis zu 5.000 Varianten sind möglich. Wir prüfen Ihre Konfiguration, klären bei Bedarf offene Punkte mit Ihnen und erstellen Ihr Angebot.

  • WITT VLDM system: Continuous monitoring of SDS and HVL

    WITT VLDM system: Continuous monitoring of SDS and HVL

    The VLDM system continuously monitors passive voltage limiters and voltage limiting devices of Classes 1, 2 and 2.2 in accordance with EN 50526-2 – including voltage surge protectors (SDS) and hybrid voltage limiters (HVL) – and reliably alerts you as soon as intervention is required. As a custom-configured system solution comprising the WB-VLDM, WB-AP and a sensor housed in a compact GRP cabinet, it is built to order to suit your specific installation – with a flexible power supply via battery, solar, auxiliary voltage or traction current (600, 750 or 1,500 V DC) and a choice of GSM, LTE, UMTS or LoRaWAN as the communication channel.

    The VLDM system continuously monitors passive voltage limiters and voltage limiting devices of Classes 1, 2 and 2.2 in accordance with EN 50526-2 – including voltage surge protectors (SDS) and hybrid voltage limiters (HVL) – and reliably alerts you as soon as intervention is required. As a custom-configured system solution comprising the WB-VLDM, WB-AP and a sensor housed in a compact GRP cabinet, it is built to order to suit your specific installation – with a flexible power supply via battery, solar, auxiliary voltage or traction current (600, 750 or 1,500 V DC) and a choice of GSM, LTE, UMTS or LoRaWAN as the communication channel.

  • WITT WB CM 7 Copper Cable Monitoring

    WITT WB CM 7 Copper Cable Monitoring

    The WITT WB-CM 7 monitors the insulation between the conductor and the shield, and between the shield and an earth point, such as water or track earth. It detects the location of the fault and reports the event to third-party systems via a log.

    The WITT WB-CM 7 monitors the insulation between the conductor and the shield, and between the shield and an earth point, such as water or track earth. It detects the location of the fault and reports the event to third-party systems via a log.

  • WITT WB-CM 4 Cable Monitoring System for DC Cables

    WITT WB-CM 4 Cable Monitoring System for DC Cables

    The WB-CM4 continuously monitors power cables and return conductors in high-voltage direct current systems up to 1,500 V DC and detects insulation faults and shield breaks at an early stage – before they lead to operational downtime or safety risks. It measures the resistance between the conductor and the shield, as well as between the shield and earth, monitors both for breaks and reports faults via potential-free relay contacts. With the option to add an additional measurement channel (WB-CM41) as well as sensors for temperature, humidity and motion, the system is suitable for light rail systems, charging infrastructure, battery buffer systems and solar installations.

    The WB-CM4 continuously monitors power cables and return conductors in high-voltage direct current systems up to 1,500 V DC and detects insulation faults and shield breaks at an early stage – before they lead to operational downtime or safety risks. It measures the resistance between the conductor and the shield, as well as between the shield and earth, monitors both for breaks and reports faults via potential-free relay contacts. With the option to add an additional measurement channel (WB-CM41) as well as sensors for temperature, humidity and motion, the system is suitable for light rail systems, charging infrastructure, battery buffer systems and solar installations.

  • WITT-TVM Traction voltage relay

    WITT-TVM Traction voltage relay

    The WITT-TVM traction voltage relay provides analogue monitoring of the traction voltage in traction power supply systems up to 1,500 V DC and reliably indicates whether a system is de-energised before parts are connected or work is carried out in live areas – for example, during maintenance work or in an emergency. It operates without an external auxiliary voltage, drawing its power from the measured voltage itself, and is supplied with up to eleven threshold parameters configured to the customer’s specifications at the factory – this is not a standard off-the-shelf product. Two separate, potential-free changeover contacts indicate when the voltage is above or below the set threshold separately; the compact DIN rail housing (IP20) can be integrated into any control cabinet.

    The WITT-TVM traction voltage relay provides analogue monitoring of the traction voltage in traction power supply systems up to 1,500 V DC and reliably indicates whether a system is de-energised before parts are connected or work is carried out in live areas – for example, during maintenance work or in an emergency. It operates without an external auxiliary voltage, drawing its power from the measured voltage itself, and is supplied with up to eleven threshold parameters configured to the customer’s specifications at the factory – this is not a standard off-the-shelf product. Two separate, potential-free changeover contacts indicate when the voltage is above or below the set threshold separately; the compact DIN rail housing (IP20) can be integrated into any control cabinet.

  • CM400 Cable Monitoring in DC Cables

    CM400 Cable Monitoring in DC Cables

    The CM 400 is a self-resetting cable monitoring device for railway applications. It detects faults in DC cables, particularly within the catenary and power supply infrastructure of electrified railway lines, thereby contributing to the operational safety and availability of the cable systems.

    The CM 400 is a self-resetting cable monitoring device for railway applications. It detects faults in DC cables, particularly within the catenary and power supply infrastructure of electrified railway lines, thereby contributing to the operational safety and availability of the cable systems.